Avalanche, Sierra, Silverado, C&K Series, 1999-2005

5.0L V8 VIN M Std 4

Print

Trouble Code: P1635



5-Volt Reference 1 Circuit Malfunction

Possible Causes:



5v VREF circuit is shorted to sensor ground or chassis ground
 
5v VREF circuit, MAP or EOP sensor circuit is shorted to (B+)
 
5v VREF circuit shorted to EGR sensor High signal circuit
 
EGR solenoid valve (and sensor) is damaged or has failed
 
PCM has failed
 

Trouble Code: P1639



5-Volt Reference 2 Circuit Malfunction

Possible Causes:



5v VREF circuit is shorted to sensor ground or chassis ground
 
5v VREF circuit or FTP sensor circuit is shorted to (B+)
 
5v VREF circuit shorted to the FTP sensor signal circuit
 
FTP sensor is damaged or has failed
 
PCM has failed
 

Trouble Code: U1000



Class 2 Communication Malfunction

Possible Causes:



Class 2 circuit is open, shorted to ground or shorted to power
 
PCM ignition power circuit(s) has a high resistance condition
 
PCM main ground circuit(s) has a high resistance condition
 
SDM (module) could be shorted pulling the voltage low
 

Trouble Code: U1016



No Communication With Powertrain Control Module

Possible Causes:



PCM Class 2 circuit is open, shorted to ground or to B+
 
PCM ignition power circuit(s) has a high resistance condition
 
PCM main ground circuit(s) has a high resistance condition
 
PCM (module) may have failed and is pulling the circuit low
 

Trouble Code: U1048



No Communication With Rear Wheel Steering Control Module

Possible Causes:



RWSCM Class 2 circuit is open, shorted to ground or to B+
 
RWSCM ignition power circuit has a high resistance condition
 
RESCM main ground circuit(s) has a high resistance condition
 
RESCM (module) may have failed and is pulling the circuit low
 

Trouble Code: U1064



No Communication With Body Control Module

Possible Causes:



BCM Class 2 circuit is open, shorted to ground or to B+
 
BCM ignition power circuit has a high resistance condition
 
BCM main ground circuit(s) has a high resistance condition
 
BCM (module) may have failed and is pulling the circuit low
 

Trouble Code: U1088



No Communication With SDM (Restraint Module)

Possible Causes:



SDM Class 2 circuit is open, shorted to ground or to B+
 
SDM ignition power circuit has a high resistance condition
 
SDM main ground circuit(s) has a high resistance condition
 
SDM (module) may have failed and is pulling the circuit low
 

Trouble Code: U1096



No Communication With Instrument Panel Cluster

Possible Causes:



IPC Class 2 circuit is open, shorted to ground or to B+
 
IPC ignition power circuit has a high resistance condition
 
IPC main ground circuit(s) has a high resistance condition
 
IPC (module) may have failed and is pulling the circuit low
 

Trouble Code: U1097



No Communication With Driver Information Center

Possible Causes:



DIC Class 2 circuit is open, shorted to ground or to B+
 
DIC ignition power circuit has a high resistance condition
 
DIC main ground circuit(s) has a high resistance condition
 
DIC (module) may have failed and is pulling the circuit low
 

Trouble Code: U1151



No Communication With Vehicle Interface Unit

Possible Causes:



VIU Class 2 circuit is open, shorted to ground or to B+
 
VIU ignition power circuit has a high resistance condition
 
VIU main ground circuit(s) has a high resistance condition
 
VIU (module) may have failed and is pulling the circuit low
 

Trouble Code: U1152



No Communication With HVAC Control Module

Possible Causes:



HVAC Class 2 circuit is open, shorted to ground or to B+
 
HVAC ignition power circuit has a high resistance condition
 
HVAC main ground circuit(s) has a high resistance condition
 
HVAC (module) may have failed and is pulling the circuit low
 

Trouble Code: U1255



Class 2 Communications Malfunction

Possible Causes:



Class 2 circuit is open, shorted to ground or shorted to power
 
PCM ignition power circuit(s) has a high resistance condition
 
PCM main ground circuit(s) has a high resistance condition
 

Trouble Code: U1305



Class 2 Data Link High or Low

Possible Causes:



Class 2 serial data line has either a high or low voltage condition on the circuit, and the module cannot identify the fault
 
One or more modules on Class 2 line has an short to power
 
One or more modules on the Class 2 line has a short to ground
 

 
label.common.footer.alt.autozoneLogo