Avenger 2008

Removal & Installation

Print


NOTE
The blower motor is located on the bottom of the passenger side of the HVAC housing. The blower motor can be removed from the vehicle without having to remove the HVAC housing

  1. Disconnect and isolate the negative battery cable.
  2.  
  3. If equipped, remove the silencer from below the passenger side of the instrument panel.
  4.  
  5. From underneath the instrument panel, disengage the connector lock and disconnect the instrument panel wire harness connector (1) from the blower motor (2).

    Click image to see an enlarged view

    Fig. Disconnect the instrument panel wire harness connector (1) from the blower motor (2)

  6.  
  7. Remove the three screws (3) that secure the blower motor and the wire lead bracket (4) (if equipped) to the bottom of the HVAC housing (5) and remove the blower motor
  8.  

To install:

  1. Position the blower motor into the bottom of the HVAC housing.
  2.  
  3. Install the three screws (3) that secure the blower motor and the wire lead bracket (if equipped) to the HVAC housing.
  4.  
  5. Connect the instrument panel wire harness connector to the blower motor and engage the connector lock.
  6.  
  7. If equipped, install the silencer below the passenger side of the instrument panel.
  8.  
  9. Reconnect the negative battery cable.
  10.  

 