Aztek, Rendezvous 2001-2005

3.4L V6 VIN E Auto 4

Print

Trouble Code: P1826



Internal Mode Switch - Invalid Range (4T65-E)

Possible Causes:



IMS Signal 'C' circuit is open or has a high resistance condition
 
Transmission has internal problems / may need an overhaul
 

Trouble Code: P1860



TCC PWM Solenoid Circuit Malfunction (4T60-E)

Possible Causes:



TCC solenoid control circuit is open or shorted to ground
 
TCC solenoid control circuit is shorted to system power (B+)
 
TCC solenoid power circuit is open (test ENG or TRANS fuse)
 
TCC solenoid is damaged or has failed
 
PCM has failed
 

Trouble Code: P1870



Transaxle Component Slipping (4T60-E)

Possible Causes:



Check the ATF level and condition (look for burnt fluid)
 
Transmission may have internal damage (a mechanical fault)
 

Trouble Code: P1887



TCC Release Switch Circuit Malfunction (4T65-E)

Possible Causes:



TCC release switch signal circuit is open
 
Turbine shaft O-ring seal leaks, oil seal rings missing/damaged.
 
TCC control valve damaged or No. 1 check ball is damaged
 
Spacer plate release exhaust blocked or case cover or spacer plate gaskets damaged
 
TSB 02-07-30-022A contains a repair procedure for this code
 

Trouble Code: U1000



Class 2 Communication Malfunction

Possible Causes:



Class 2 circuit is open, shorted to ground or shorted to power
 
PCM ignition power circuit(s) has a high resistance condition
 
PCM main ground circuit(s) has a high resistance condition
 
SDM (module) could be shorted pulling the voltage low
 

Trouble Code: U1016



No Communication With Powertrain Control Module

Possible Causes:



PCM Class 2 circuit is open, shorted to ground or to B+
 
PCM ignition power circuit(s) has a high resistance condition
 
PCM main ground circuit(s) has a high resistance condition
 
PCM (module) may have failed and is pulling the circuit low
 

Trouble Code: U1048



No Communication With Rear Wheel Steering Control Module

Possible Causes:



RWSCM Class 2 circuit is open, shorted to ground or to B+
 
RWSCM ignition power circuit has a high resistance condition
 
RESCM main ground circuit(s) has a high resistance condition
 
RESCM (module) may have failed and is pulling the circuit low
 

Trouble Code: U1064



No Communication With Body Control Module

Possible Causes:



BCM Class 2 circuit is open, shorted to ground or to B+
 
BCM ignition power circuit has a high resistance condition
 
BCM main ground circuit(s) has a high resistance condition
 
BCM (module) may have failed and is pulling the circuit low
 

Trouble Code: U1088



No Communication With SDM (Restraint Module)

Possible Causes:



SDM Class 2 circuit is open, shorted to ground or to B+
 
SDM ignition power circuit has a high resistance condition
 
SDM main ground circuit(s) has a high resistance condition
 
SDM (module) may have failed and is pulling the circuit low
 

Trouble Code: U1096



No Communication With Instrument Panel Cluster

Possible Causes:



IPC Class 2 circuit is open, shorted to ground or to B+
 
IPC ignition power circuit has a high resistance condition
 
IPC main ground circuit(s) has a high resistance condition
 
IPC (module) may have failed and is pulling the circuit low
 

Trouble Code: U1097



No Communication With Driver Information Center

Possible Causes:



DIC Class 2 circuit is open, shorted to ground or to B+
 
DIC ignition power circuit has a high resistance condition
 
DIC main ground circuit(s) has a high resistance condition
 
DIC (module) may have failed and is pulling the circuit low
 

Trouble Code: U1151



No Communication With Vehicle Interface Unit

Possible Causes:



VIU Class 2 circuit is open, shorted to ground or to B+
 
VIU ignition power circuit has a high resistance condition
 
VIU main ground circuit(s) has a high resistance condition
 
VIU (module) may have failed and is pulling the circuit low
 

Trouble Code: U1152



No Communication With HVAC Control Module

Possible Causes:



HVAC Class 2 circuit is open, shorted to ground or to B+
 
HVAC ignition power circuit has a high resistance condition
 
HVAC main ground circuit(s) has a high resistance condition
 
HVAC (module) may have failed and is pulling the circuit low
 

Trouble Code: U1255



Class 2 Communications Malfunction

Possible Causes:



Class 2 circuit is open, shorted to ground or shorted to power
 
PCM ignition power circuit(s) has a high resistance condition
 
PCM main ground circuit(s) has a high resistance condition
 

Trouble Code: U1305



Class 2 Data Link High or Low

Possible Causes:



Class 2 serial data line has either a high or low voltage condition on the circuit, and the module cannot identify the fault
 
One or more modules on Class 2 line has an short to power
 
One or more modules on the Class 2 line has a short to ground
 

 