Dakota 2006-2007

Removal & Installation

Print


NOTE
The blend door actuator cannot be adjusted or repaired and, if damaged or faulty, must be replaced. After installation the new actuator must be calibrated using a scan tool.

  1. Disconnect and isolate the negative battery cable.
  2.  
  3. Remove the instrument panel.
  4.  
  5. Remove the three screws that secure the blend door actuator to the top of the HVAC housing.
  6.  
  7. Disconnect the HVAC wire harness connector (4) from the blend door actuator.
  8.  
  9. Remove the blend door actuator from the HVAC housing.

    Click image to see an enlarged view

    Fig. On 2005 models the Blend Door Actuator (2) is mounted with screws (1) on TOP of the HVAC housing (3). Harness location is shown at (4)

  10.  

To install:

  1. Position the blend door actuator onto the top of the HVAC housing. If necessary, rotate the actuator slightly to align the splines on the actuator output shaft with those on the blend-air door linkage.
  2.  
  3. Install the three screws that secure the blend door actuator to the HVAC housing. Tighten the screws to 2 Nm (17 in. lbs.).
  4.  
  5. Connect the HVAC wire harness connector to the blend door actuator.
  6.  
  7. Install the instrument panel.
  8.  
  9. Reconnect the negative battery cable.
  10.  
  11. Calibrate the actuator using a scan tool.
  12.  

 
label.common.footer.alt.autozoneLogo