Envoy, Rainer, Trailblazer 2006-2007

Recovery & Recharging

Print

The J-43600 is a complete air conditioning service center for R-134a. The ACR 2000 recovers, recycles, evacuates and recharges A/C refrigerant quickly, accurately and automatically. The unit has a display screen that contains the function controls and displays prompts that will lead the technician through the recover, recycle, evacuate and recharge operations. R-134a is recovered into and charged out of an internal storage vessel. The ACR 2000 automatically replenishes this vessel from an external source tank in order to maintain a constant 5.45-6.82 kg (12-15 lbs) of A/C refrigerant.

The ACR 2000 has a built in A/C refrigerant identifier that will test for contamination, prior to recovery and will notify the technician if there are foreign gases present in the A/C system. If foreign gases are present, the ACR 2000 will not recover the refrigerant from the A/C system.

The ACR 2000 also features automatic air purge, single pass recycling and an automatic oil drain.

Refer to the J-43600 ACR 2000 manual for operation and setup instruction.

Always recharge the A/C System with the proper amount of R-134a.The correct amount is as follows:



Refrigerant charge without rear A/C-1.9 lbs. (0.86 kg)
 
Refrigerant charge with rear A/C-2.65 lbs. (1.2 kg)
 

A/C Refrigerant System Oil Charge Replenishing



If oil was removed from the A/C system during the recovery process or due to component replacement, the oil must be replenished. Oil can be injected into a charged system using J-45037. For the proper quantities of oil to add to the A/C refrigerant system, refer to the following:



Accumulator Replacement-2 oz. (60 ml); Add PAG oil equal to the amount of oil drained from the old accumulator plus the specified additional amount.
 
Compressor Replacement-2 oz. (60 ml); a Sanden scroll compressor containing 240 ml of oil is used on this model year. If more than the specified amount of oil was drained from a component, add the equal amount of oil drained.
 
Condenser Replacement-1 oz. (30 ml). If more than the specified amount of oil was drained from a component, add the equal amount of oil drained.
 
Evaporator Replacement-3 oz. (90 ml). If more than the specified amount of oil was drained from a component, add the equal amount of oil drained.
 
Total System Oil Capacity-8 oz. (240 ml)
 

 