Jeep Wagoneer/Commando/Cherokee 1957-1983 Repair Information

Thermostatically Controlled Air Cleaner System (TAC)

Print

DESCRIPTION AND OPERATION



See Figure 1

Click image to see an enlarged view

Fig. Fig. 1: Thermostatically controlled air cleaner (upper view open and lower view closed)

This system consists of a heat shroud which is integral with the right side exhaust manifold (left side on the 8-350), a hot air hose and a special air cleaner assembly equipped with a thermal sensor and a vacuum motor and air valve assembly.

The thermal sensor incorporates an air bleed valve which regulates the amount of vacuum applied to the vacuum motor, controlling the air valve position to supply either heated air from the exhaust manifold or air from the engine compartment.

During the warm-up period when underhood temperatures are low, the air bleed valve is closed and sufficient vacuum is applied to the vacuum motor to hold the air valve in the closed (heat on) position.

As the temperature of the air entering the air cleaner approaches approximately 115ºF, the air bleed valve opens to decrease the amount of vacuum applied to the vacuum motor. The diaphragm spring in the vacuum motor then moves the air valve into the open (heat off) position, allowing only underhood air to enter the air cleaner.

The air valve in the air cleaner will also open, regardless of air temperature, during heavy acceleration to obtain maximum air flow through the air cleaner.

 