Liberty, Wrangler 2006-2007

Removal & Installation

Print


NOTE
Prior to performing this procedure, turn the ignition key to the On position and set the A/Cheater control in the mid-temperature position and wait 10 seconds.

  1. Disconnect and isolate the negative battery cable.
  2.  
  3. Disconnect the wire harness connector from the blend door actuator located at the bottom of the HVAC housing .
  4.  
  5. Remove the three screws that secure the blend door actuator to the HVAC housing and remove the actuator
  6.  

To install:

  1. Position the blend door actuator onto the bottom of the HVAC housing. If necessary, rotate the actuator slightly to align the actuator output shaft with the blend door linkage.
  2.  
  3. Install the three screws that secure the blend door actuator to the HVAC housing. Tighten the screws to 17 inch lbs. (2 Nm).
  4.  
  5. Connect the HVAC wire harness connector to the blend door actuator.
  6.  
  7. Reconnect the battery negative cable.
  8.  

  1. Remove the HVAC housing.
  2.  
  3. Disassemble the HVAC housing.
  4.  
  5. Lift the blend door pivot shaft out of the pivot hole in the bottom of the lower half of the HVAC housing .
  6.  

To install:

  1. Position the blend door pivot shaft into the pivot hole located in the bottom of the lower half of the HVAC housing.
  2.  
  3. Assemble the HVAC housing.
  4.  
  5. Install the HVAC housing.
  6.  

 
label.common.footer.alt.autozoneLogo