Pickup 1997

Charging the System

Print

Specific to:

Nissan Pickup 1996-1997


CAUTION
Air conditioning refrigerant or lubricant vapor can irritate your eyes, nose, or throat. Be careful when connecting service equipment. Do not breathe refrigerant or vapor.


CAUTION
If accidental system discharge occurs, ventilate work area before resuming service. Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.

  1. Connect a R-134a refrigerant recover/recycling/charging station (A) to the high-pressure service port (B) and the low-pressure service port (C), following the equipment manufacturers instructions.
  2.  
  3. Add the same amount of new refrigerant oil to the system that was removed during recovery.
    WARNING
    Charge the system with the specified amount of R-134a refrigerant. Do not overcharge the system; the compressor will be damaged.

  4.  

 