Suzuki Forenza, Reno 2003-06

Evacuating the System

Print

The unit tank must contain a sufficient amount of R-134a refrigerant for charging. Check the amount of refrigerant in the tank. If there is less than 3.6 kg (8 pounds) of refrigerant, add new refrigerant to the tank. Refer to the manufacturer's instructions for adding refrigerant.

  1. Verify that the high-side and the low-side hoses are connected to the A/C system. Open both the high-side and the low-side valves on the unit's control panel.
  2.  
  3. Open both the gas and the liquid valves on the tank.
  4.  
  5. Start the vacuum pump and begin the evacuation process. Non-condensable gases (mostly air) are vented from the tank automatically during the recycling process. You may hear the pressure being released.
  6.  
  7. Check for leaks in the system. Refer to the manufacturer's instructions for the charging station in use.
    NOTE
    Any oil removed from the A/C system during the recovery process must be replenished.

  8.  

 